There are two different levels or types of extended monitor, A and B. Locations 0177
and 0178 determine which zone types are to be monitored by each extended monitor
type. Entering a full function user code followed by the digit 3 will place the system
in extended monitor mode type A or enter the 4 digit for extended monitor type B.
When entering extended monitor the system responds with "MONITOR ON" through
the inside speaker.
NOTE: You can only enter the extended monitor mode when the system is disarmed.
If the system is in extended monitor mode it will automatically exit that mode when
the system is armed.
Fire Cut Off and Reset: The length of time the system will stay in alarm without a disarm before the system
stops the sirens and waits for another zone activation. Fire cut off and reset is not
permitted in a UL installation.
5 Day Cycle: The automatic arm/disarm feature will occur every day unless the 5 day cycle is
included in the "Automatic Arm / Disarm" option. The 5 day cycle is Monday
through Friday.
Force Arm w/ Open To automatically force arm around open zones, include force arm around open zones
in
Zones: the total for the "Automatic Arm / Disarm" option. If this option is not used the panel
will not automatically arm if a zone is open.
Force Bypass-unbypassed:The option "zones bypassed by force arm auto unbypassed at disarm" is useful if the
option "open zones automatically bypassed at force arm" is enabled. With both
options set, all zones that are bypassed at force arm will be unbypassed when the
system is disarmed. Bypass is not permitted in a UL installation.
Ignore Dial Tone: This removes the dial tone detect in the panel for cellular backup units that do not
supply dial tone.
Key Combinations: The chart is used for setting custom key combinations. To change a key
combination, select the column for the keypad and the desired key or combination.
Enter the Key function in the location.
Local Telephones: Allows use of the code on in-house touch tone phones.
Local Phone Access Code:Code required to access the system from a local phone.
Master Functions: Adding this option allows a code to enter into bypass mode, extended monitor,
change user codes, and activate smoke reset.
Monitor Trouble: The system can speak and indicate a high current situation, control low battery, and
a failure to complete a digital communication as trouble conditions at the keypad.
Entering 001 will enable speech and show the condition at the keypad while 000
disables this feature. This feature must be enabled in a UL installation.
Multiple Reports: Multiple reports will be sent to the central station in one phone connection as
opposed to hanging up and re-dialing for each report.
Mute External Speakers: This option sends all tones to the inside speaker and is adjustable with the inside
speaker volume adjustment. The external speaker output is turned off. The main use
of this feature is for testing alarm activations.
No Entry Delay in HOME:When enabled, this option will cause the exterior delay zones to become instant
when the system is armed to HOME.